Physitemp-instruments BFS-MP CSA Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Physitemp-instruments BFS-MP CSA. Physitemp Instruments BFS-MP CSA User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
PHYSITEMP INSTRUMENTS INC
154 Huron Avenue
Clifton NJ 07013 USA
Tel: 973-779-5577
Fax: 973-779-5954
OPERATING MANUAL
EB BFS-MPCSA 6310 Rev2 04/07
BFS-MP SERIES FREEZING STAGES
Models BFS-3MP, BFS-5MP, BFS-30MP
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - BFS-MP SERIES FREEZING STAGES

PHYSITEMP INSTRUMENTS INC154 Huron AvenueClifton NJ 07013 USATel: 973-779-5577Fax: 973-779-5954OPERATING MANUALEB BFS-MPCSA 6310 Rev2 04/07BFS-MP SER

Strona 2 - OPERATING INSTRUCTIONS

BFS/MP SERIES THERMAL STAGES1.0 GENERAL DESCRIPTION1.1 Physitemp manufactures three freezing stages for use with microtomes. All stages operate in the

Strona 3 - GENERAL INSTRUCTIONS

WARNING! DO NOT USE DRY ICE ON TOP OF THE STAGESeveral customers have reported using Dry Ice (CO2) to speed up thefreezing of tissue specimens mounted

Strona 4

OPERATING MANUALBFS-MP FREEZING STAGESFOR MICROTOMESBFS-3MP, BFS-5MP, BFS-30MPCONTENTSSECTION PAGE1.0 GENERAL DESCRIPTION 22.0 UNPACKING AND CHECKING

Strona 5

APPENDIX 2OPERATING INSTRUCTIONSECV-1 ELECTRICALLY OPERATED SOLENOID VALVEThe ECV-1 is supplied with an AC line cord and 12 VDC desktop power supply.1

Strona 6

APPENDIX 1OPERATING INSTRUCTIONS FOR PHYSITEMP PUMP AND TANK UNIT, PTU-31. Unscrew cap. Fill reservoir with 5 gallons of distilled water.2. Connect ex

Strona 7

7.0 MAINTENANCE, WARRANTY AND SERVICE7.1 MAINTENANCEThe stage needs no maintenace at all. It may be cleaned as necessary with a soft cloth, water or d

Strona 8 - FRONT PANEL CONTROLS

6.0 SPECIFICATIONS6.1 CONTROLLEROperating Range: BFS-3MP and 5MP: -35°C to ambientBFS-30MP: -40°C to ambientDigital Readout Resolution: 0.1°CAccurac

Strona 9 - CONNECTIONS

collar in an anti-clockwise direction. An ohmmeter will be required to make several readings on thestage connector. Once the connector has been remove

Strona 10 - BFS/MP SERIES THERMAL STAGES

4.7 REMOVING SPECIMEN FROM STAGEPress the Freeze/Thaw switch and hold in the QUICK THAW position for a few seconds. Allow thestage to warm up until sp

Strona 11 - EB BFS-MPCSA 6310 Rev2 04/07

4.0 OPERATING INSTRUCTIONS4.1 Ensure that the POWER Switch on the rear panel of the controller is in the OFF position4.2 Connect the AC power cord to

Strona 12

3.0 SETTING UP THE SYSTEMThis section gives instructions for set-up if the equipment is to be used with tap water: If a Pump and Tank Unit is to be us

Komentarze do niniejszej Instrukcji

Brak uwag